4:1 balun design and operation


4:1 balun design and operation

Home ]Up ]

 

Balun Test  Sleeve baluns   
Balun and Transformer Core Selection   
Verticals and Baluns   
Antenna Tuner Baluns   
Common mode current   
Common-Mode Noise   
toroid balun winding   
Steel wool balun

 

Two Modes of a
Balun Line
Transformer

There is a
tendency to view a
balun in much too
simplistic terms.
The most common
errors stem from not fully
understanding how the system
terminating the
balun behaves, and
not understanding
how that system
interacts with the
balun. We commonly
consider only the load
impedance or SWR, and
of course RF power levels, when
discussing baluns.
Load impedance (or to a lesser detail SWR) describes
differential (across
the line) characteristic,
and is
easily understood
and explained. Power is easily understood. The natural motivation to stay with
what we easily understand is the root of misunderstanding baluns.

One
of the most
important things, the
common mode voltage
driving a balun or
common mode
impedance of a
system, is largely misunderstood or ignored.


Common mode

impedance
can really be almost
anything from a few ohms to several thousand ohms, and is
often unrelated to
differential
impedance. Perhaps
common mode is ignored
because it is a bit
more complex, inconvenient to measure, and
varies greatly even in what appear to be similar systems.

At times common
mode excitation can
be phenomenally
high. One antenna
design I’ve worked
in particular on
comes to mind,
because it had the
largest spread in
voltage and
impedance between
common mode and
differential (normal
transmission line
mode) mode I’ve ever
observed. With a
few hundred watts of
power, with a differential mode
impedance of 50 j0
and 1:1 SWR, the
common mode voltage
driving the balun in
this troublesome
system was several
thousand volts.
String of beads 50
beads long would
literally shatter or
melt through Teflon
coax (even though the
SWR was 1:1)
with only a few
hundred watts of
transmitter power.

In contrast to
that system, I
worked on a small
“magnetic” loop
antenna. The small
loop presented a
very high common
mode impedance with
almost no common
mode voltage, and
even though the loop
was a
balanced system a good balun
made absolutely no
difference in
performance or
common mode current. For any
feed line length,
with or without a
balun,
common mode current
on the feed line to
the loop was essentially
zero.

In the above
systems, the first
example (the dipole) could be much
worse than a
balanced balun test
load simulated by a
center-tapped
resistor. The second
case, the very small
“magnetic” loop, appeared to
the feed line almost
like a fully
floating resistor.
This points to one
very real
conclusion, a balun
test with a fully
floating resistor is
like the testing the
balun in a system
were the balun is
not needed; a system
where the balun
serves no useful
purpose.

The amount of current that flows into the feeder as common mode is determined
by the common mode impedance looking back down each conductor of the feed line,
and the electrical potential that drives that impedance. The antenna terminals
in effect push back against the feed line, just like it is a generator. The other
“foothold” is the electrical mass or common mode impedance of the antenna
itself, as the antenna behaves like a radial or counterpoise working against the
feed line. In general very
large symmetrically
fed half-wave
antennas have a very
low common mode
impedance near the antenna. This is because in common mode, a half-wave dipole
looks like two opposing 1/4 wave radials! The dipole
presents a pretty
stiff source voltage
at the feed line terminals.
Each conductor in
the feed line is
effectively driven
by a voltage
that is around
half the voltage
appearing across the antenna’s
feedpoint, the electrical mass of the antenna being the footing to push current
down into the feed line.

(Asymmetrical
antennas, feed lines
that parallel or run
inside elements
(like end-fed
dipoles or skirt
vertical dipoles), and many other
systems generally drive
the feed line from a common mode voltage source that is much higher than the
voltage across the feed line from conductor-to-conductor.) 

Looking at it
this way it is easy
to see why the small
balanced loop
develops very little
common mode current
under any feed line
length condition,
and why a dipole can
significantly excite
the feed line. The
loop has a very high
common mode
impedance, not
nearly as low as a
small floating
resistor, but still
high enough make the
loop act like a poor counterpoise. This makes it difficult to push
common mode current into the
feed line. The dipole
on the other hand looks
like a pair of 1/4
wave radials, each
providing a very low
impedance for common
mode voltages to
push against and
drive current into
the feed line
conductors. On the test bench, the
center tapped resistor that is grounded at the center is very close to a dipole.
Common
mode current and
imbalance in the
antenna (or center tapped load) is limited
primarily by the
common mode
impedance looking
into the source (the feed line or balun). In a balanced line, both conductors are
excited with common mode. An unbalanced line, the coaxial
feed line, behaves in common mode as
a single-wire
transmission line
with the shield as
the sole conductor.

It’s easy to see
the actual load a
balun (or transmission line) connects to varies over quite
wide extremes in common mode. The load on the balun or transmission line almost
never appears as a
small floating resistor. In a very small small loop, the antenna behaves like a
resistor divider with one side going to
a small
capacitance. In
other cases, like the
half-wave dipole example, the load on the
balun (or feed line) appears similar to a
center tapped 50-75
ohm resistance.

One of the worse
jobs in the world is
to design a balun
that behaves
properly in all
installations at an advertised power rating. As a matter
of fact, it is
impossible to have a power rating that applies to all situations. A balun
that works great in one
application can greatly
misbehave in
another.

For
example, a low-loss
core high-Q core (i.e. air or a
low permeability
iron or ferrite) can
handle a great deal
of power without
heating, but it is
also the least
reliable core for
suppression of
common mode. A high-Q core that never heats is often not effective in balancing
currents, and can actually increase common mode currents and decrease system
balance.

If
I wanted a balun
that would never get
hot, I would use a
core that had
virtually no common
mode suppression at
all! Consider the
case of a balun with
a 10 +j1000 ohm
common mode
impedance, as we
might find in a
large air-core balun
with a common mode Q
of 100.  If the
common mode
impedance at the
insertion point is
anything above -j500 ohms in reactance, the
balun will actually
increase imbalance
and unwanted common
mode current!! This
is why I never use
air-core baluns
unless I understand
the system the balun is
being used in, and I know
the system is
compatible with that style of
balun.

Only one type of
impedance will
always suppress
common mode under
any system
condition. That
impedance is a
pure
resistance. Adding a
pure resistance in
series with any
common mode
impedance, no matter
what the reactance
might be, will
always reduce common
mode current. We cannot say the same thing for high-Q chokes.

 

The transformer
or winding in the
balun has two
distinct functions:

 It
can act as a
transmission line
,
conveying energy
along the parallel
path of the two
conductors in the windings,
carrying the
differential mode
(transmission line
mode) signal to the
load as any transmission
line would. In this
mode the core has
minimal effect if
any. The core could
be replaced with
anything from air to
steel with very
little effect on
performance. The
small effect that
might occur comes
because the
transmission line in
the balun is less
than perfect. There
will be a small
amount of electric
and magnetic flux
outside the area of
the parallel wires,
and those fields
often impinge on the
outermost surface
area of the core and
other conductors or
dielectrics outside
the conductors
making up each
specific area of
transmission line.
This is the
differential mode of
the transformer
windings, where two
conditions are met:

1.) Voltages at
any point along the
transmission line
are of opposite
polarity from
conductor to
conductor.

2.) Conductor
currents, at all
points, are
traveling in
opposing directions
in any section of
the transmission
line. 

It can act
like a conventional
transformer
,
conveying energy
through direct
electric or magnetic
field coupling (or a
mixture of both)
between conductors.
In this mode the core
has a significant
effect on frequency
response and
efficiency. The
core, depending on
frequency, has a
major impact on
impedance and
performance, often
having the greatest
impact on system
impedance at lowest
operating
frequencies and
system losses at all
operating
frequencies. This is
the common mode of
the transformer
windings, where
one
or
more of following three
conditions are met:

1.) Voltages
between conductors
at any point are the
same polarity.

2.) Currents in
each conductor at
any point are not
equal or are not
flowing in opposite
directions.

3.) One conductor
in the parallel
winding acts a
source that drives an
external load. This is the secondary winding. The other conductor in the winding acts as
a
load for an external
power source. It is excited end-to-end in one winding conductor, and is the
primary winding.

 

Most transformers
or windings in a
balun act a bit like
both modes. The
general system
design goal
is to have the
transmission line
effect be most
important, because
it is the mode where
the balun is most easily made
to have the widest
bandwidth and lowest loss.

Dipole Antenna
Model

The following is
an example of how
severe the stress on
a balun can get, and
why feed line length
must be adjusted to
provide moderate
impedances to
baluns. This model
is for an 80-foot
high 1/2-wave 80
meter dipole with
1.2 inch spaced
balanced line with
thin polyethylene
insulation on each
conductor.

80 meter doublet model balun ladder line

 

This is the
80-foot high
80-meter dipole over
perfect ground.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feedpoint details dipole model

This is a zoom of
the feedpoint. Distance of wire 7 (from 5 to 6) is one foot. In
order to feed the
antenna and not
violate model
guidelines, I had to
spread the feed line
wires from 1.2
inches out to 1
foot. I shorted the
feed line wires with
wire 7, and inserted
a current source in
number 7 set for the
current produced by
1000 watts of power
into the feed line.

The current source in a model is perfect, being totally independent of
ground.

Wire 8 is used to
test common mode in
a balun, in this
case assuming a
current balun.

 

 

 

 

 

 

 

Let’s look at
what happens in the
balun with common
mode.

Across the source
at 7 we have:

 EZNEC+
ver. 5.0
ladder line
dipole 6/6/2010
7:17:54 PM

—————
SOURCE DATA
—————
Frequency = 3.6
MHz

Source 1 Voltage
= 1942 V at
-63.0 deg.
Current = 1.134
A at 0.0 deg.
Impedance = 777
– J 1525 ohms
Power = 1000
watts
SWR (50 ohm
system) = 75.441
(400 ohm system)
= 9.837

We have 1942 V
RMS differential
mode voltage. This
is what excites the
transmission line in
a 1:1 balun, and
what appears from
terminal to
terminal.

In common mode
from the left
terminal with a
5000 j0 common mode
impedance balun we
have:

 EZNEC+
ver. 5.0
ladder line
dipole 6/6/2010
7:05:40 PM
———- LOAD DATA ——–

Frequency = 3.6
MHz

Load 1 Voltage =
781.6 V at
-49.31 deg.
Current = 0.1563
A at -49.31 deg.
Impedance = 5000
+ J 0 ohms
Power = 122.2
watts

Total applied
power = 1000
watts

With a difficult-to-obtain 5,000 ohm
j0 common mode balun
impedance, the cores
would dissipate 122
watts or 12.2% of
applied power.

There are two
ways to fix this,
make the balun
primarily reactive
or alter the
feed line length.

Looking at a
slightly reactive
balun common mode
from using a higher
Q core:

 EZNEC+
ver. 5.0
ladder line
dipole 6/6/2010
7:37:01 PM
—————
LOAD DATA
—————

Frequency = 3.6
MHz

Load 1 Voltage =
815.4 V at
-43.32 deg.
Current = 0.1939
A at -61.32 deg.
Impedance = 4000
+ J 1300 ohms
Power = 150.3
watts

Total applied
power = 1000
watts

We can see that
balun core
dissipation would
now increase to 15%
of applied power.
Current unbalance
would also increase
considerably from
.156 amperes to
.1939 amperes.

 EZNEC+
ver. 5.0

ladder line
dipole 6/6/2010
7:44:35 PM

—————
LOAD DATA
—————

Frequency = 3.6
MHz

Load 1 Voltage =
1254 V at -57.69
deg.
Current = 0.2508
A at -146.54
deg.
Impedance = 100
+ J 5000 ohms
Power = 6.292
watts

Total applied
power = 1000
watts

Balun common mode
current is up to .25
amperes, the highest
value yet. Balun
heat would be down
to a cool 6 watts.
This balun core
would barely get
warm.

The above is
NOT WORSE

CASE,
just a random case I
picked from typical
feed line lengths. It
is possible for all
of these numbers to
get worse, and for
the addition of a
high-Q balun that is
primarily all
reactance to seriously
unbalance the
antenna system. This is
true even with a
very high reactance!
Many times a cool-running balun is a
sign of a balun not
doing its job.


Typical 80 meter
Doublet on 40 Meters

The typical
80-meter dipole or
doublet on 40 meters
with a 65 foot long
feed line is an
example of another
stressful load for a
balun.

ladder line
dipole 6/8/2010
11:10:04 AM
—————
SOURCE DATA
—————
Frequency = 7.2
MHz

Source 1 Voltage
= 2137 V at
-28.56 deg.
Current = 0.5329
A at 0.0 deg.
Impedance = 3522
– J 1917 ohms
Power = 1000
watts
SWR (50 ohm
system) = 91.305
(400 ohm system)
= 11.439

ladder line
dipole 6/8/2010
11:10:04 AM
—————
LOAD DATA
—————
Frequency = 7.2
MHz

Load 1 Voltage =
899 V at -36.6
deg.
Current = 0.1798
A at -36.6 deg.
Impedance = 5000
+ J 0 ohms
Power = 161.6
watts

Total applied
power = 1000
watts

By not changing
height of the
antenna, and only
changing feed line
length to 99 feet
(from 1/2 wave above
to approximately 3/4
wavelength), we have
the following:

ladder line
dipole 6/8/2010
11:30:50 AM
—————
SOURCE DATA
—————
Frequency = 7.2
MHz

Source 1 Voltage
= 494.3 V at
53.91 deg.
Current = 3.434
A at 0.0 deg.
Impedance =
84.78 + J 116.3
ohms
Power = 1000
watts
SWR (50 ohm
system) = 5.287
(400 ohm system)
= 5.134

ladder line
dipole 6/8/2010
11:30:46 AM
—————
LOAD DATA
—————
Frequency = 7.2
MHz

Load 1 Voltage =
202.1 V at 53.82
deg.
Current =
0.04041 A at
53.82 deg.
Impedance = 5000
+ J 0 ohms
Power = 8.166
watts

Total applied
power = 1000
watts

Balun core heat
is reduced from 162
watts or 16% of
transmitter power, to
8 watts or 0.8% of
transmitter power.
feed line length is
critical to optimum
balun performance.
While it isn’t
always the case that
balun heat or core
stress is always low
with a low
terminating
impedance on the
balun, it is
generally true that
balun core stress
always increases
with load impedance
terminating the
balun.

I only use an
air-core choke balun
in very specific
applications where I
know what the effect
will be. When the
system is unknown, I
use a core that
produces a 
primarily resistive
common mode
impedance. If the
balun overheats, I
alter feed line
length. This will
often correct the
problem without
changing the balun’s
design.

Some entire balun
handbooks and many
articles have been
written without an
understanding of how
the balun actually
interacts with the
antenna system. The
truth is… if a
balun never
overheats at high
power in any
application, it may
not be acting like a
balun at all with real loads. Some baluns appear perfect on the test bench while
failing to balance many real-world systems.

Range of Common Mode Impedances

One way to measure common mode impedance is to short the feed line terminals
and feed the system as a single wire antenna. Here is the common mode impedance
of another 80-meter doublet or dipole fed with 99 feet of open wire line on 40
meters.

 — common mode source
impedance–

Frequency = 7.2 MHz

Impedance = 98.86 – J 272.3 ohms
 

5000 j0 CM balun losses

Load 1 Voltage = 216.4 V at -123.54 deg.
Current = 0.04327 A at -123.54 deg.
Impedance = 5000 + J 0 ohms
Power = 9.363 watts

Total applied power = 1000 watts

Total load power = 9.363 watts
Total load loss = 0.041 dB

 –differential mode SOURCE
DATA —

Frequency = 7.2 MHz
Source 1 Voltage = 480.7 V at 53.82 deg.
Current = 3.524 A at 0.0 deg.
Impedance = 80.52 + J 110.1 ohms
Power = 1000 watts
SWR (50 ohm system) = 5.045

(400 ohm system) = 5.359

 

We see that when common mode and differential source impedances are
low, a balun can do a very effective job. feed line common mode impedance can
range from a few ohms to several thousand ohms, and this impedance critically
affects balun and system performance. If we insert a balun at a point driven
with very high voltages balun heating can be catastrophic. If the balun doesn’t
heat, from inadequate common mode impedance or being largely reactive, the system will
often just go out of
balance.

4:1 Transmission Line Balun with Balanced Load

The circuit below shows a 4:1 transmission line current balun in operation feeding a balanced
load. This
balun is a 4:1 ratio
and feeds a balanced
200-ohm load. This
load would be very
similar to the
terminal impedances
of a full-size
perfectly
symmetrical antenna,
like a folded dipole, a large and
perfectly
symmetrical loop, or
a symmetrical “T”
matched antenna with
a feed line length
that is neither
worse case nor
optimum feed line
length. 
The load resistors
have to be grounded
in the center for
one simple reason.
For any system to be
perfectly balanced,
or for a balanced
transmission line to
not radiate, line
currents have to be
exactly equal and
opposite and voltage
with respect to the
outside world has to
be exactly equal and
opposite at any and
all points along the
system. Many people
miss this, and think
the only requirement
is having equal and
opposite currents at
one point in the
system is enough to
ensure full system
balance. 

Another serious flaw is testing a balun or analyzing a balun using a floating
load, like a physically small resistor placed across balun output terminals. One
popular UnUn and Balun handbook shows a lack of understanding of how to analyze,
measure, and test baluns! It actually suggests power is evenly divided between
the two choke baluns making up a 4:1 current balun. Nothing is further from the
truth! Most likely the misconception that the transformers share equal
dissipation comes from a lack of understanding of field theory and antenna
systems, especially common mode impedances.

Let’s look at power dissipation using a SPICE model. Logic tells us with an
infinite common mode load impedance (R5), like a physically small resistor,
balun voltage and heating will be equal in each winding:

Balun Spice model flaoting load

 

 

This model uses a 10 million ohm common mode impedance, allowing the magnetizing
impedance in transformers T1 and T2 to determine voltage division. With equal
transformers, voltage will divide evenly. This is the flawed case used by some
balun designers and published in some balun handbooks and white papers.

 

 

 

 

 

 

balun upper arm voltage

 

 

We see the model agrees with theory.

 

 

 

 

 

 

Balun lower arm voltage

 

Balun upper and lower terminal voltages are in a 3:1 ratio, and the sum of
voltages equals balun source voltage.

Balun core dissipation would only be 1/2 watt in each core with 200 watts
delivered to the 200-ohm load.

Core heating and dissipation is evenly split.

 

 

Now let’s look that the upper extreme common mode impedance likely to occur
in real-world systems:

Upper limit common mode balun

 

 

In this case we set common mode Z at 5000 ohms. This would be similar to a
1/4 wave long open wire line feeding a large matched balanced load, like a
folded dipole antenna.

 

 

 

 

 

 

 

high common mode Z matched  load

 

 

Upper terminal R3 top is 133.2 volts.

 

 

 

 

 

 

 

high common mode impedance 4:1 load voltage

 

 

Lower terminal voltage is now 66.44 volts, now a ratio of only 2:1 in
voltages. Balun cores are now unevenly heated, with 223 mW dissipation in the
top core (T1) and 883 mW dissipation in the bottom core (T2).

This is still a successful balun because the applied voltage is so low, but
it demonstrates how uneven core heating increases rapidly with very slight
amounts of common mode current. T2 heats four times more than the other core,
T1!

 

 

Running through the model again but with a 650-ohm common mode impedance, a
very typical middle for common mode impedance, we again find uneven core heating
becomes a problem. The system has only 21 milliwatts
in T1, and 1.61 watts in T2. This is a core heating ratio
of 77:1 between the two core!!! The upper core barely does anything.

A second factor in heating is the voltage across the load resistance, R3 and
R4. In this case we only have 200 volts across the resistors because we have a
1:1 load SWR (200 ohm load across an assumed 200 ohm balun output) at 200 watts.
If the feeder has a high SWR, like a 450-ohm line feeding a dipole or doublet
antenna, and if we pick a combination of antenna and feed line length that
present a high load impedance to the balun, we can have severe balun heating
problems even with modest power. This is because balun core losses are so high.

This tells us there are two general rules for minimizing balun heating:

  • Common mode impedance should be as high as possible on the balun output.
  • Differential mode impedance should be as low as possible across the
    balun output.

We can also conclude any balun test that assumes equal distribution of losses
between cores is an impossible real-world situation. There isn’t an antenna system
anywhere that has an infinite common mode impedance, and virtually every system
is under 5000 ohms common mode impedance. Most antenna systems are probably 1000
ohms or less common mode impedance, so we can just ignore any contribution of
the upper transformer to power handling.

Note: This was just confirmed by actual measurements of antennas here. An
article is soon to follow showing measured data. 7/23/2010

This also excludes the idea that a dual transmission line balun like a 4:1
can use a single core, an idea that was promoted in a popular Balun and UnUn
handbook. The flawed idea the load looks like a floating resistor results in all
sorts of misunderstandings about balun behavior.

My Earlier Simple Models and Analysis

This is an earlier model I used, and the method I use on the
test bench here. It is easy to see it is much closer to the real world than the
floating resistor (infinite common mode impedance) model. As a matter of fact if
every system presented infinite common mode impedance to the balun, there would
be no need for baluns in any system!

In this balun,
the transmission
line transformers
clearly behave in
two very distinct
modes. They act as
1:1 transformers,
and they also act as
transmission lines.
In the first
example, one of
perfect balance, the
transmission line
transformers operate
primarily as
transformers. T2 is
excited across
e-f
by 10
volts with g-h
being the secondary,
while T1 is excited
by theoretically
exactly equal and
opposite currents in
the windings and
thus has zero core
flux density.

4:1 balun how it works

T1 voltages and currents:

Current flowing through
a-b is 0.1 ampere

Current flowing through
c-d
is 0.1ampere in
the opposite
direction

This results in zero voltage across
a-b and
c-d

Volt-turns in T1 is zero under
a perfectly  balanced condition, since current in windings
flows opposite directions. R1 current through
a-b is equaled by T1 from
d-c, so
ampere turns magnetizing
the core oppose each
other. T1 has no flux in core, since volt-turns =
zero.   T1 can be shorted from
a-b or from
c-d with no effect.

 

 

T2 voltages and currents:

e-f has the same current as flows through
c-d,
c-d has the same as a-b,
0.1 ampere

g-h must also have the same current as flowing through
e-f

R2 has equal current with R1, 0.1 ampere

this means g-h has 10 volts, phase as shown

Ampere turns (flux density) in T2 is R2 current times turns. T2 core carries
all the flux in a balanced-voltage balanced-current (perfect balance) condition.

Real Transmission Line 4:1 Balun  Unbalanced Voltage R1 top =0V

The same balun with perfect unbalance in load, top grounded:

4:1 balun perfect imbalance

In this case we
new voltages.

T2 now has twice
the volt-turns of
T1, and with equal
windings and cores
this causes flux density in T2
to be twice that of T1.

T1 cannot be
replaced by a short
from a-b
or c-d.

T1 is now required to allow voltage at top of  R1 to
deviate from the
original +10 volts,
in this case
reaching 0 volts. .
Shorting a-b or
g-h would
now prevent proper operation.

 

 

 

 

 

 

 

Real 4:1 Transmission Line 4:1 Balun Bottom Grounded

4:1 Balun transformer current balun

Now we see flux density in T2 is zero.

g-h or
e-f can be shorted

Flux density in T1 is maximum, flux in T2 is zero.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-Core Dual Transmission Line Balun

It has been proposed
in a few places that a single core can be used
to create two 1:1 choke baluns in a
transmission line balun, and
this will still
create a good current balun.
We cannot combine
cores
unless each transformer has IDENTICAL flux density
under all conditions
of load balance.

Here’s what happens to our baluns above if we have a
single core that provides a
closed path for all flux
from all windings:

single core transmission line balun

With identical turns on each
winding and a common core
causing equal flux
levels to pass through
every winding,
voltage across each winding
would be held equal. This means any solution
of voltages to the load must provide:

The sum of voltages from
c to e must equal supply voltage

Output voltage across load is now 20v, so we have a correct 4:1 impedance
ratio but:

Load is voltage unbalanced, that means if we ground center tap or either
end of the load we upset voltages and currents in the system. We no longer
have a balun, we have an unbalanced voltage source.

Any tolerance of the three balance conditions a current balun must
maintain would only occur if the core had flux leakage. The worse the core, the
better the balun will behave.

The book
Baluns and UnUn’s
proposes a transmission line balun like the balun above could be wound
on a single core. That isn’t true. A balun configured as
shown to the left must be on two
separate cores or it will not remain balanced.
We cannot hold each
core to the same
flux density or the
load will be
seriously
unbalanced.

The source end of the transmission line must always be fed with equal and
opposite currents, and must always have the source applied in differential
across the line at the input (source end) only.

In a transmission line (excited as shown above) energy is conveyed from
end-to-end in a TEM mode. This mode requires, under the conditions of matched
load, voltage between conductors along the line to be in a precise relationship
with current. In the case of a 50 ohm line with 50 watts, current (through
vector) would be 1 ampere while voltage (across vector) would be 50 volts. This
is true anywhere along the line.

transmission line mode

 

If we mismatch the line, the product  of voltage across and current
through the line at any point is still 50, even though the ratio of E to I will
change.

We have two conditions then that apply to any load. 

  • In a matched condition voltage across and current through at any point are
    always in the same ratio, and that ratio equals line impedance and the product
    always equals power applied. Transmission currents in the two conductors are
    always exactly equal and opposite
    at any single
    point along the
    line.
  • In a mismatched line the voltage across and current through the line at any
    point has a vector product equal to power applied, and the ratio of voltage and
    current at any point is equal to the line operating impedance at that point.
    Transmission currents are always equal and opposite.   

Here is a way
to have equal
currents but not be
in a transmission
line mode:

Transmission line transformer

If we take the output from the conductor normally used as the opposing conductor in
a transmission line,
we still have
opposing current
directions. The electrical equivalent of
this “transmission
line” circuit is shown here:

Transformer balun

This obviously is not a transmission line
mode, but instead is a simple basic
primary/secondary transformer.

Let’s see if this system follows the same rules as a transmission line in TEM
mode.

Coaxial transformer

Notice in all cases above voltage across the line at any and all points is
zero. This means no energy is conveyed along the line in TEM (transmission line)
mode, even though currents are exactly equal and opposite. This system does
follow the basic rules of a conventional transformer, in that the secondary
ampere-turn product always equals primary-ampere turn product in order to keep
secondary magnetic flux in equilibrium with primary flux density.

For example, if we have a lossless one turn primary and two turn secondary
transformer with one ampere flowing in the primary, we know we must have 1/2
ampere in the two-turn secondary. This is independent of impedance between
conductors.

In TEM mode, in a matched condition, the across and through vectors (E and I)
at any point multiply to give us power flowing past that point. In
“transformer mode”,
the product is zero
because voltage
between conductors
is at any point is
zero. We can change
even “line
impedance”, and the
change will have
very little effect
on SWR!

In transformer
mode:

  • Instead of energy being conveyed to the load by conduction currents
    flowing through a direct wired path (as in a transmission line balun),
    energy is now transferred through the “balun” via flux coupling
    between conductors. This means the balun core is
    at least partially involved in all energy
    transfer.  
  • The fact the core is directly subjected to magnetizing forces and is
    excited directly by source voltage greatly limits power/ mismatch range of
    the balun. A normal transmission line balun can tolerate extreme mismatches
    if proper materials are used, but the same size and quality materials in a
    transformer-style balun handle less power into matched loads, and
    significantly less power into highly mismatched
    loads.    
  • In a normal transmission line (even one used in a balun) the series
    inductance of the conductors is balanced by the shunting capacitance between
    the conductors. This means if we terminate the transmission line correctly,
    VSWR bandwidth is extremely wide.

 