Short Verticals

 

 


Antenna System Sales
 through CTR Engineering, Inc

 

 Short verticals, while providing construction simplicity and space
advantages, can present electrical problems.  Let’s walk through some
cases.

 

The 43-foot vertical has become the new standard of vertical antenna heights.
A typical 43-foot vertical vertical presents the following 50-ohm SWR curve.
43-ft verticals with 50-ohm feeders have three low-SWR points. SWR is:

1.8 MHz >100:1
3.5 MHz >100:1
7.0 MHz 7:1
10.1 MHz 23:1
14 MHz 27:1
18.1 MHz 2:1
21 MHz 12.4:1
24.9 MHz 18.4:1
28.5 MHz 4.8:1

Low SWR:

5.8 MHz  = 1.38:1 17.07 MHz 1.03:1 29.6 MHz = 1.22:1

 

 

 

Normalizing to 200-ohms will show us what it looks like through a perfect 4:1
current balun or un-un. Notice the only SWR points above 10:1 occur below 5.2
MHz. SWR is still off scale below 4 MHz :

 

On 80 and 160 meters, with 100 watts radiated power, RMS base
voltages and currents will be:

 

Frequency = 1.82 MHz

RMS base voltage = 4501 V at -89.81 deg.

Peak voltage = 6364.4 V
Current = 6.558 A at 0.0 deg.
Impedance = 2.325 – J 686.3 ohms
Power = 100 watts
SWR (50 ohm system) > 100 (200 ohm system) > 100

 

Frequency = 3.5 MHz

RMS base voltage = 849.9 V at -87.91 deg.

Peak voltage = 1201.75 V
Current = 3.221 A at 0.0 deg.
Impedance = 9.641 – J 263.7 ohms
Power = 100 watts
SWR (50 ohm system) > 100 (200 ohm system) = 56.848

 

 

160-meter Operation 80-meter Operation 43 ft Vertical

Mismatched Operation

Mismatched operation will generally be accompanied by considerable loss, with
most of the stress concentrated in the matching transformer. With a feed line SWR
over 100:1, insulation in the antenna will not be an issue. feed line and
matching system losses will dominate.

 

Tuner or Matching at Antenna Top

The superior system would be top loading with a hat or “L” wire. Unless the
wires are folded back when operating higher bands, some sort of trap or
switching system will be necessary. Construction of high power isolating traps
or switches is a significant challenge, unless losses in a poor ground or
matching system limits antenna power.  

 

Single 35 ft wire at 45 degrees.

 

 

L
 

Frequency = 1.82 MHz

RMS Base Voltage = 2069 V at -89.5 deg.

Peak base V = 2926V   (no hat voltage 6400V)

Current = 5.486 A at 0.0 deg.
Impedance = 3.322 – J 377.1 ohms
Power = 100 watts
SWR (50 ohm system) > 100 (200 ohm system) > 100

 

Frequency = 3.5 MHz

RMS Base Voltage = 45.46 V at -28.49 deg.

Peak base V = 64.3V

Current = 2.503 A at 0.0 deg.
Impedance = 15.97 – J 8.664 ohms
Power = 100 watts
SWR (50 ohm system) = 3.236 (200 ohm system) = 12.551

 

 

 

SWR Plot

 

 

 

 

Four 35′ wires at 45-degrees

 

 

Base voltages at 100 watts radiated power with four 35-ft hat wires:

Frequency = 1.82 MHz

RMS Base Voltage = 804.6 V at -88.63 deg.

Peak base V = 1138 V (no hat voltage
was 6400V)

Current = 5.214 A at 0.0 deg.
Impedance = 3.678 – J 154.3 ohms
Power = 100 watts
SWR (50 ohm system) > 100 (200 ohm system) = 86.729

 

Frequency = 3.5 MHz

RMS Base Voltage = 414.8 V at 83.99 deg.

Peak base V = 586.53 V

Current = 2.303 A at 0.0 deg.
Impedance = 18.86 + J 179.2 ohms
Power = 100 watts
SWR (50 ohm system) = 37.035 (200 ohm system) = 19.155

 

 

 

SWR Plot with 4-wire hat:

 

 

 

 

Base matching on 160 and 80 will produce the highest efficiency, unless some
form of hat or top loading wire is used.

 

 

 

Voltage causes arcing and instantaneous operational failures, while current
is generally a time average failure from heat. Consequentially, arcing failure
voltages must be considered by instantaneous peak voltage. Heating
is by long term average RMS voltage or current.

The arc distance of 5kV is about 1/2 inch for optimum dry conditions. Most
“legal power” antenna tuners will only handle 2.5 kV peak or less. This means on
80-meters, a typical 1500-watt antenna tuner will allow 150-watts of equivalent
radiated power before failing. When running high power, that 150-watts can be
from a combination of feed line losses, ground losses, and matching network
losses. It is a real limit.

The base insulator below is for a 43ft vertical that was mounted over a good
ground system and fed with a good loading coil on 80-meters. The insulator
failed at 700-1000 watts peak transmitter power.

 

The limitation for a given radiated power on
160 and 80 meters is normally going to be insulation somewhere in the system.