The Knight T-150 and T-150A have a generally poor reputation for spectral
purity. As originally designed, the T150 and T150A have very high spurious signal levels.
Although not perfect without major redesign, they are easily improved if we take time to understand the flaws.

The primary
flaw in the Allied Knight T150 series is the very poor choice of VFO frequency,
and poor unwanted VFO fundamental and/or unwanted VFO harmonic rejection by following
stages. Poor harmonic rejection is caused by marginal Q tuned circuits between
stages, by grossly excessive coupling between stages, and by low output tank Q on 80
meters.

The T-150 uses a very poor choice of VFO frequencies. On 80 meters, the VFO
runs between 1.75-2 MHz. This is typical of many VFO’s, and was done to move the
VFO off straight-through bands. Running on straight through bands, like an
80-meter VFO on 80 meters, can aggravate oscillator pulling, and in severe
cases, cause early stages to oscillate. This is normally not a problem on
80-meters, because a spurious 1.75 MHz below or above the band is a fairly large
percentage of frequency away. For example, on 80-meters, the 1.75 fundamental is
50% of the operating frequency. The third VFO harmonic is on 5.25 MHz, about 50%
above the 80-meter band.

On 40-meters, the T-150 VFO operates between 3.5 and 3.713 MHz.  This
creates a major spurious signal issue. Now, on bands on and above 40 meters, the
spurious multiples are only 3.5 MHz. above the band, or below the band. This
means, on ten meters, the VFO spurious signals are only 12.5% below and above
the ten-meter band. This low percentage difference can cause problems filtering
spurious signals, and increases the number of spurious signals.

      

Here is the original spectral plot of a T150 on 80 meters:

Knight t150a spurious

 

 

160-meter signal, while on 80 meters, is only -21 dBc below 80 meter desired
signal. Notice spurious signals appear at every multiple of the VFO frequency,
every 1.75 MHz.

 

 

 

 

 

 

 

 

 

 

5.25 MHz signal, the third harmonic of VFO, is -27.28 dBc.

This is primarily caused by over-coupling between stages and poor selectivity in oscillator and buffer
circuits, and aggravated by low tank Q on 80 meters.

 

 

 

 

 

 

 

 

 

 

7.0 MHz signal is only -35 dBc 80-meter signal. This is primarily caused by
low tank Q on 80 meters. I’m working on a fix for that.

 

 

 

 

 

Modifications

SAFETY

The T-150 does not have a bleeder resistance across the lower electrolytics
in the power supply (350V B+ line). I added a 50k 7 watt resistor from one
terminal of the 40 uF electrolytic to chassis ground, although a 100k 2 watt
metal film or oxide resistor will work.

PERFORMANCE CHANGES 

Note: These mods
are subject to change as I spend more time working with the T-150.

Referring to the schematic below:

 

T150 and T-150A mods knight spurious

 

 

 

 

 

 

 

 

 

 

 

 

 

Looking at the schematic above, we see the T-150 is seriously over-coupled
between stages, and has far too large of an RF choke on the VFO.  For
example, L-4 and C-12 can be used to form a high pass filter. This is usually
desirable, because lower harmonics of the VFO almost always provide far too much
drive anyway. In this stage , knight used 5 mH as the choke, offering a very
high impedance far below the AM broadcast band. Aggravating the situation, they
then used a 470 pF coupling capacitor. This extends low-frequency response of
the VFO output system down into the 100-200 kHz range, far below the lowest
transmitter frequency of 3.5 MHz.

This pattern of poor component value choice extends through all RF stages,
including the 6CL6 “oscillator” stage (used as a buffer in VFO mode) and 7189
buffer/multiplier stage.

To correct this, we can:

  1.  Change L-4 to 100uH such as JW Miller 4632
  2. Change C-12 and C17 to 27pF 1kV any common style, disc or mica
  3. Change C-23 to 68pF 1kV. Any common style, disc or mica 
  4. The tap at L-10 moves to tube end near parasitic suppressor.

 This results in the following change in output:

 

t150A modified

 

 

 

160 meter feedthrough is now -34.3 dBc. This is a 13 dB improvement.

 

 

 

 

 

 

 

 

 

 

 

 

5.25 MHz harmonic of VFO is now -36.1 dBc. This is an 8.8 dB improvement.

 

 

 

 

 

 

 

 

 

 

 

7 MHz harmonic is now -37.6 dBc. This is a 2.6 dB improvement. This harmonic
does not improve much with driver system mods, because it is primarily caused by
poor tank operating Q on 80 meters.

 

 

 

 

 

 

 

 

 

 

 

Deeper Changes (under work)

The 6CL6 crystal oscillator/buffer stage lends itself to easiest changes when
using a more involved modification. For 80 meters, I replaced L-6 with a choke
from Mouser Electronics. I used a Vishay-Dale part number 70-IMS5-22  in
parallel with a 27 pF 1 kV capacitor. This changed 160 feedthrough from the -34
dBc obtained with the simple mod to -45 dBc, a 10 dB
improvement over the simple mod and -24 dB better than stock!

 With this single change, the unwanted signal on 5.5 MHz changed from
the -36 dBc obtained in the simple mod to -55 dBc . This is a
-19 dB improvement at 5.5 MHz over the simple modification, and about -27 dB
better than stock. At this point, the T-150 is not much worse than any other rig
on 80 meters.