Testing for Stability



Testing for Stability


Home ]Up ]

 

Home Test for Amplifier Stability

For homebrew amplifiers or modified suppressors in
transmitters or transmitters,
this is the simplest possible nearly
100% reliable test procedure. This procedure applies to any adjustable network amplifier stage
requiring parasitic suppression. Testing for stability always involves varying
load impedances presented to the output device.

 

Setup:

Operating the amplifier stage with the highest safe voltage, terminate the
output in a dummy load.

Use the smallest possible line fuses! Know where the
“off” switch is so you can turn it off if the amplifier starts oscillating.

 

 

Starting on the highest band:

With open input port

1.) Set the loading control at 50% capacitance or more

2.) Engage the amplifier so it shows normal quiescent current on CW mode (if
applicable)

3.) Rotate plate control through its range while carefully watching grid current and
plate current. There should be no sign of movement. If there is any meter
movement, be careful. You have an unstable amplifier.

4.) Repeat in SSB mode (if applicable)

5.) Change band to next lower band

I.) Short input and repeat and repeat 1-5

II.) Terminate input with 50 ohms (can be very small resistor) and repeat 1-5

 VHF oscillations are not always
band independent, but VHF oscillations are most affected by the PLATE
tune control. The LOAD or ANTENNA control usually has very little effect
on VHF oscillations.

HF oscillations are generally very band sensitive, and
worse on the highest bands. Some non-neutralized amplifiers (even grounded-grid
amplifiers) can be unstable at upper HF with the above test. Examples of
unusually unstable amplifiers at HF are the Clipperton L, GLA1000, and LA1000. 
The GLA1000 and LA1000 are unstable because the control grid is tied to
the cathode, so the tubes do not have good shielding from anode to
cathode.

Amplifiers often unstable at HF include the Collins four
811A amplifier (30L1) and Yaesu 572B tube (FL2100 series) amplifiers.

Amplifiers occasionally
unstable at HF include the SB200 series and the AL811 (not H)
model. This is because these amplifiers lack neutralization, and use
tubes with long skinny grid leads.

In grounded grid amplifiers, be sure all
grid pins are grounded
with the lowest RF impedance path possible. If the amplifier is unstable at VHF,
inductance of the parasitic suppressor should be increased or resistor value
changed until the amplifier
is fully stable.

Going back and forth between resistance value and number of
turns, some resistance value requiring the least parasitic inductance will be optimum.
After finding the best compromise values of resistance and inductance, add about 20% more
inductance. If the resistor overheats on ten meters, increase power rating of
the resistor. HF resistor heating will peak on the highest band, generally ten
meters in an HF amp.

Here is the general procedure for finding optimum suppressor
values, if you really want to optimize the system. It requires several suitable
resistor values and some time:

1.) Run HV and filament at maximum allowable voltage. Start with
much more inductance than required, and approximately 100 ohms of non-inductive
resistance from a metal composition or metal film resistor.

2.) Activate the amplifier with normal resting current, but do
not apply RF drive power

3.) Working and down one band at a time through all bandswitch
positions, tune the PLATE capacitor watching for an increase in plate current or
grid current (no RF excitation)

4.) If stable, remove high voltage and bridge suppressor turns
with solder. Repeat until the amplifier just becomes unstable at VHF.

5.) With the amplifier on this band with the PLATE control
setting, adjust the resistance up or down. Find a value that makes the stage
stable. In general longer and thinner anode path connections require more
resistance. If you don’t want to go through this bother, use 50-100 ohms on
average length anode connections, and 100-250 ohms on exceptionally long or thin
anode leads. Both the required inductance and required resistance increase with
long anode leads.

6.) Remove more turns by bridging them with solder. Retest again
by bridging in other resistances.

7.) When satisfied resistance is in the right range, find the
inductance where stability appears perfect. Add about 20% more inductance after
that.

8.) Retest thoroughly. If the resistor overheats when running
full power on the highest band, use a higher wattage resistor.

 

When I design commercial or amateur amplifiers, a series of rigorous tests
are made. This is the commercial protocol:

Most Reliable Spurious Test Protocol

1.) A three step load is connected to the input port through a zero or
ten foot cable. These loads are open, short, and 50 ohms.

2.) A variable frequency and adjustable power exciter is also available.

3.) The output port is terminated in a 5000 watt 30 dB attenuator pad.
This pad drives a calibration-certified Agilent spectrum analyzer. Sweep is
>30 kHz to 3 GHz, but is also narrowed to sweep +- 500 kHz from the exciter
when it is used.

4.) An adjustable bias source is connected.

5.) High voltage or Vs is set at highest voltage feasible.

Starting on highest band with dummy load on input, while watching all PA
current meters and spectrum analyzer, these steps are followed for each
operating frequency range:

A.) open input, no transmission line, bias at 75% of rated output device
quiescent dissipation, all controls are rotated through all positions.

B.) open input, transmission line, bias at 75% of rated output device
quiescent dissipation, all controls are rotated through all positions.

C.) shorted input, no transmission line, bias at 75% of rated output
device quiescent dissipation, all controls are rotated through all
positions.

D.) shorted input, transmission line, bias at 75% of rated output device
quiescent dissipation, all controls are rotated through all positions.

E.) open input, no transmission line, bias at 5% of rated output device
quiescent dissipation, all controls are rotated through all positions.F.) open input, transmission line, bias at 5% of rated output device
quiescent dissipation, all controls are rotated through all positions.

G.) shorted input, no transmission line, bias at 5% of rated output
device quiescent dissipation, all controls are rotated through all
positions.

H.) shorted input, transmission line, bias at 5% of rated output device
quiescent dissipation, all controls are rotated through all positions.

I.) Change band and repeat this series

Starting on highest band with exciter on input, while watching all PA current
meters and spectrum analyzer, these steps are followed for one central frequency
in each operating frequency range:

a.) 10% input, no transmission line, all controls are rotated through all
positions.

b.) 10% input, transmission line, all controls are rotated through all
positions.

c.) 75% input, no transmission line, all controls are tuned for normal
operation .

d.) 75% input, transmission line, all controls are tuned for normal
operation.

f.) change band and repeat this series

note: Solid state amplifiers are tested with and without a high
pass filter for each band tested on the output.